Skip to content

About

Desktop app (macOS/Windows/Linux) for ZOYI ZT703S/ZT706S on OpenOSC: scope, DMM, generator, Bode, protocol decoding (RS-422/485, DMX512, Sony 9-pin, VISCA, TSL), files, Wi-Fi/BLE. Fork of OpenOSC Panel.

Resources

Stars

1 star

Watchers

0 watching

Forks

 
 

Repository files navigation

OpenOSC Panel

Your ZOYI ZT703S on OpenOSC firmware, driven from the browser. Oscilloscope, signal generator, Bode plotter and multimeter on a big screen, over one USB cable. No drivers, no install, no backend. Your data never leaves your machine.

Build Version License: MIT Firmware: OpenOSC 0.21.4+ only Stack: Vite · React · TypeScript · Tailwind

OpenOSC Panel: oscilloscope, generator, Bode and multimeter for the ZOYI ZT703S on OpenOSC firmware, shown as the multimeter, oscilloscope and generator views

Important

This panel works only with the OpenOSC firmware. The stock ZOYI firmware has no remote control over USB. Still on stock firmware? See below.

Features

Multimeter

  • Up to a week of continuous logging, 1.8 million readings, with the whole run on the chart and every spike and overload still visible.
  • Your measurements are safe. After a page reload, a tab or browser crash or a power cut, the panel offers to restore the recording and you carry on logging.
  • Start and stop logging on the reading itself: log only while a current is above or a voltage below a value you set, once or every time it happens. No need to watch the meter.
  • Trend chart, histogram and statistics describe exactly the readings you logged; one click exports them as CSV.
  • Battery capacity and drain tests: a DC current log counts the charge in mAh / Ah, by the same rule as the meter's own counter.
  • Thermocouple types B, E, J, N, R, S and T, besides the meter's own type K: the panel converts the meter's millivolts (NIST ITS-90) with a cold-junction temperature you enter.
  • Safety reminders: a red warning above 60 V DC or 30 V AC, and a reminder to move the red lead when you leave the current ranges.

Oscilloscope

  • The device's own measurements (frequency, Vpp, RMS, duty and more) and the hardware frequency counter on each channel.
  • An FFT you can measure on: peak frequency and level, two markers for differences, and plain notes on the panel when a spectrum can't be trusted.
  • Catch glitches and bad pulses with Pulse width, Runt and Rise/fall triggers: set the polarity, the levels and a time limit like 50us (OpenOSC 0.21.19 or newer).
  • Export the full capture record as CSV, not just what's on screen.
  • Analyses on the full record: harmonics with THD, SINAD and ENOB, supply ripple (mean, rms, peak-to-peak) and LTC timecode, drop-frame included.

Bode plot

  • One click sweeps the generator and re-ranges each channel as the gain changes, then reads off the −3 dB corner and roll-off.
  • Sets the scope up for the sweep itself, whatever you left it at, and puts your scope and generator settings back when it's done, trigger included.

Generator

  • Type frequencies the way you say them: 10k, 2.5 MHz, 500 mHz.
  • Keeps running while you work in another view.

Serial decoding and broadcast protocols

  • The device's own decoder on a big screen (UART, RS-232, RS-485, DMX512 and more): status, counters, an event table and timeline, with plain hints when the record can't be decoded. Export the result as the same CSV the device writes, or save it on the device.
  • Decode both directions of an RS-422 link at once: CH1 and CH2 as two lines, or CH1−CH2 as a pair, with automatic levels and baud rate, parity, stop bits, breaks and framing errors.
  • Read the bytes as studio protocols: Sony 9-pin, VISCA, Pelco-D, Pelco-P, TSL UMD 3.1/4.0/5.0 and DMX512/RDM, with named commands, checksum OK/bad and a 512-slot DMX grid that marks changed slots; click up to 8 slots (or 16-bit coarse/fine pairs) to plot them over time with spikes, ±1 jitter and split 16-bit values flagged. Sony 9-pin Status Data replies read as deck state (play, record, servo lock, ...), and reply times and byte gaps are checked against the 9 ms / 10 ms protocol limits. Each reply is checked against its command (expected reply type and length, NAK reasons). The timecode the deck reports (LTC, VITC, Timer-1) is checked against its transport state at 24, 25, 29.97 DF or 30 fps: jumps, frozen time in PLAY, time running in STOP, invalid values and DF violations. With house LTC on the other channel, the deck's reported time is compared with it (offset, lag, drift, freezes and LTC dropouts). The Device Type reply names the deck (Sony, Blackmagic HyperDeck and others) with its 525/625 standard and notes the commands that deck does not support. VISCA commands are paired with their ACK and Completion per camera and socket (also on one shared RS-485 line), with reply times, missing replies and error replies such as Command buffer full. Pan/tilt position commands and inquiry replies fill a per-camera state table. RDM discovery answers (no BREAK) are split off and their UID decoded; collisions show as such. RDM responses show their parameter data (DEVICE_INFO, start address, personality, labels, NACK reasons), and a responder table lists each fixture's address range with overlaps marked red. TSL UMD traffic builds a bus table, one row per display address with tally lamps, text and recent changes highlighted. Pelco-D and Pelco-P traffic fills a per-address table (last command, pan/tilt speed, zoom/focus/iris, presets, aux, bad checksums). A Pelco-P stream opened as Pelco-D gets a hint and a one-click switch. Identify scores every decoder on the captured bytes and ranks the likely protocols, with a note when the line rate looks wrong. Paste hex to try it without a device, or save a capture with its byte times and open it again later: every timing check runs offline. Work offline on the connect screen opens the Protocol panel, saved captures and the examples/ without a device.
  • A workbench for undocumented links: telegram lengths, a field map per shape, a checksum hunter (sums, XOR, CRCs) and request/reply latency, exported as JSON or CSV. An A/B diff of two captures shows which telegram a button press adds or changes.
  • Line check for DMX512 and RS-422/485: E1.11 timing (BREAK, MAB, break-to-break, gaps) and differential levels, polarity and idle state from the scope record.

Files

  • Browse the device's files without Recovery mode (OpenOSC 0.21.9 or newer, either USB profile): screenshots, DMM logs, saved waveforms, decoder results and FRA sweeps. Download, unpack .GZ captures, delete, and preview: images, a waveform plot, a DMM session's trend, a decoder result read as studio protocols.

Everywhere

  • Remote front panel: a live mirror of the device screen and its keys (F1–F4, MENU, arrows, MODE, HOLD, AUTO, REL) with short and long presses and keyboard shortcuts (SYST:KEY, OpenOSC 0.21.15 or newer; the mirror works on every supported firmware).
  • Control the device from your computer. The settings you'd otherwise dig for with the small screen and buttons (timebase, volts per division, trigger, meter function and range, generator shape and level) are a click away on a big screen, and changes made on the device's own buttons show up in the panel too.
  • Lock the device's buttons while you work from the computer, and save a picture of the device's own screen.
  • The panel switches the device between its scope and multimeter modes for you, in about a second.
  • For advanced users: a console to send the firmware's text commands (SCPI) directly.
  • Four colour themes, two dark and two light, for the whole app. Pick one with the palette button; it is remembered.
  • Install it as an app from the browser's address bar: no installer, and it works offline once you've opened it online.

What you need

  • A ZOYI ZT703S with OpenOSC 0.21.4 or newer (tested on 0.21.4 to 0.21.19). Older or unrecognised firmware gets a warning before connecting, and features it lacks stay off. The ZT706S should work too, but nobody has tried it on real hardware yet. Reports welcome.
  • OpenOSC 0.21.9 or newer is recommended: the scope updates about three times faster, short glitches stay visible on long captures, and the measurements come from the device itself. Older firmware still works, with measurements computed in the browser.
  • On the device: USB on in Settings → Files & USB, and performance profile 200/100 (faster profiles switch USB off).
  • Chrome, Edge, Opera or Firefox 151+ on desktop. Safari and iOS have no Web Serial.

Caution

The USB port is not isolated. Probe ground is tied to your computer's ground. Never measure mains while the cable is in.

Stock firmware?

The stock firmware has no remote control, so the panel can't connect to it. Two options:

  • Keep it and use Multimeter·Live (open the app). It reads the multimeter through the meter's serial output over a USB-UART adapter or Bluetooth. Multimeter only: no scope, generator or control.
  • Install OpenOSC. The OpenOSC README and wiki cover installing it and going back to stock. Flashing firmware is at your own risk.

Good to know

  • Scope and multimeter can't run at the same time: they are separate USB profiles on the device. The generator keeps running across the switch.
  • The multimeter recording is kept until you press Clear data. At 1.8 million readings logging stops: export the CSV, then clear to start a new one.
  • Apart from your colour theme and the multimeter recording, nothing is saved between visits: panel settings, scope captures and Bode results start fresh.
  • Each online launch loads the latest version. If a new one comes out while the panel is open, it asks first (Update / Later) and never reloads on its own, so an unsaved log is safe.
  • One device, one tab: the serial port is exclusive.

Independent project, not affiliated with ZOYI or ZOTEK, and separate from the OpenOSC firmware project. Product names are used only to identify the hardware.

Run it yourself

The quickest way is the live app. To run it locally:

npm install
npm run dev

Open http://localhost:5173 and click Connect device.

To host your own copy, run npm run build and serve dist/ from any static host with HTTPS. On GitHub: fork the repo, set Settings → Pages → Source to GitHub Actions, then run Actions → Deploy to GitHub Pages → Run workflow.

Contributing

Issues and pull requests are welcome, ZT706S reports most of all. Before sending code, run npm run build, npm run check and npx fallow.

License

MIT

About

Desktop app (macOS/Windows/Linux) for ZOYI ZT703S/ZT706S on OpenOSC: scope, DMM, generator, Bode, protocol decoding (RS-422/485, DMX512, Sony 9-pin, VISCA, TSL), files, Wi-Fi/BLE. Fork of OpenOSC Panel.

Resources

Stars

1 star

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages